Native coverage of Law 24/2017 (Gelli-Bianco)
Modelling of the risk management functions required by Art. 1 of Law 24/2017, with traceability of adverse events and of the corrective actions required once fully in force from 16 March 2026.
Buyer's guide · Clinical Risk
The operational checklist for Risk Managers and Medical Directorates: 34 criteria for assessing clinical risk management software in Italian National Health Service (SSN) organisations.
With Law 24/2017 (Gelli-Bianco) fully in force from 16 March 2026, the risk management function in SSN organisations is no longer optional: it must be traceable, accountable and integrated with the organisation's clinical governance. Choosing the supporting software becomes a strategic decision, not just a technological one.
This guide brings together 40 operational criteria for assessing Risk Management software in ASL, ASST, AOU and IRCCS. Each criterion has a stable code (e.g. CN-01) that can be reused in tender specifications, in an RFI or in a demo evaluation grid. The aim is to make objective a comparison that, by its nature, tends to be influenced by the preferences of the evaluators.
The checklist is organised into 8 thematic areas: regulatory compliance, incident reporting and workflow, risk register and governance, analytics and reporting, integrations, data security, usability and supplier.
Criteria tailored to ASL, ASST, AOU and IRCCS: language, legislation and operational workflows recognisable from day one.
8 thematic areas, from Gelli-Bianco to interoperability, for an objective comparison between suppliers.
Each criterion has a stable code designed to be reused in an RFI, an evaluation grid or demo minutes.
The checklist
Each criterion is designed to be verifiable during a demo or formally requested from the supplier. The code next to the title (e.g. CN-01) lets you reference it unambiguously in tender specifications, in an evaluation grid or in minutes.
Area 01 · 7 criteria
Compliance with Law 24/2017 (Gelli-Bianco), Legislative Decree 502/1992, ministerial recommendations on sentinel events and audit trail requirements.
Modelling of the risk management functions required by Art. 1 of Law 24/2017, with traceability of adverse events and of the corrective actions required once fully in force from 16 March 2026.
Automatic generation of the annual report with aggregated data for the Medical Directorate, in an editable format and with a template compliant with regional guidance.
The 19 ministerial recommendations on sentinel events are mapped in the system as risk categories that can be activated and associated with indicators.
Compatibility with the SIMES data flow (Sistema Informativo per il Monitoraggio degli Errori in Sanità, the Italian information system for monitoring errors in healthcare) and with equivalent regional data flows.
Every change to events, PARMs and claims must be logged with user, timestamp and reason; the log must be exportable and non-modifiable.
Support for the Claims Assessment Committee (CVS) with a document repository, case statuses, deadline tracking and dealings with insurers.
Reports and exports designed for the periodic requests of the Region, AGENAS, insurers and control bodies.
Area 02 · 6 criteria
Quality of reporting, anonymity, case handling workflow and root cause analysis tools.
Average time to complete a report (near miss, adverse event, fall) under one minute for ward staff.
The ability to report anonymously without requiring a named login and without indirectly tracking the user through IP address/device.
Specific forms for near misses, adverse events, sentinel events, falls, medication errors, patient identification, HAIs.
Configurable statuses, roles and escalation SLAs: case acceptance, analysis, corrective actions, closure, effectiveness check.
The system must guide reactive Root Cause Analysis and proactive FMEA/FMECA with templates, not just a free-text notes field.
Each corrective action has an owner, deadline, status, outcome of the effectiveness check and planned follow-up.
Area 03 · 5 criteria
Single risk register, Annual Risk Management Plan (PARM), process mapping and governance of continuous improvement.
A single central register classified by area, process, likelihood, impact and status of actions; filterable by operational unit.
The PARM is not a static document: the system tracks priorities, actions, progress, owners and KPIs in real time.
The ability to model processes (e.g. surgery, drug therapy, transfusion) and link them to the identified risks.
Every risk in the register can be followed through to the related adverse events, ongoing actions and outcome/experience indicators.
Differentiated visibility and permissions for Strategic Management, Hospital Site, Department and Operational Unit.
Area 04 · 4 criteria
Dashboards, indicators and reporting for Strategic Management, quality offices and external communication.
Patient safety KPIs visible without manual steps: events per operational unit, average closure times, overdue actions, sentinel events.
Time series of events, near misses, claims and corrective actions to assess the effectiveness of risk management over time.
Metadata-rich exports to feed regional data warehouses, mandatory information flows and internal technical working groups.
Comparison between Operational Units and Hospital Sites on consistent indicators, with controls on the risk of exposing personal data.
Area 05 · 5 criteria
Ability to communicate with the clinical record, ADT, CUP, FSE, quality systems and regional platforms.
Authentication integrated with Active Directory or the organisation’s IdP, with automatic provisioning/deprovisioning of roles.
APIs for associating events, reports and claims with the correct patient without manually re-entering personal details.
Support for standard interoperability formats with a view to FSE 2.0 (the Italian Electronic Health Record) and exchange with regional applications.
Documented REST/GraphQL APIs (OpenAPI) for internal automations and custom integrations without exclusive dependence on the vendor.
Non-conformities, ISO 9001 audits and risk management reports must be able to converge without duplicate data entry.
Area 06 · 6 criteria
Protection of health data, GDPR compliance, national cloud, technical and organisational measures.
Health data resides on infrastructure qualified by ACN (formerly AgID) or on the organisation’s own infrastructure; the vendor must guarantee data sovereignty.
Record of processing activities, DPIA on the processing of clinical data and healthcare staff data, management of data subject rights.
Data encrypted at rest (AES-256) and in transit (TLS 1.2+), with documented key management.
Field/module-level permissions, segregation of duties between clinical, administrative and audit roles.
Backup policies, restore testing, RTO/RPO stated in the contract and consistent with the criticality of health data.
The supplier falls within NIS2 scope or demonstrates equivalent measures: incident notification, supply chain, Art. 20 training.
Area 07 · 3 criteria
User experience for ward staff, accessibility, responsive design and guided pathways.
Responsive forms tested on mobile and tablet: ward staff must be able to report even from the bedside.
Compliance with the AgID guidelines on public administration accessibility and compatibility with screen readers.
Guided tours, contextual help and embedded training materials to reduce the time-to-competence of healthcare staff.
Area 08 · 4 criteria
Supplier credentials, SLAs, development roadmap, support in Italian and references.
Verifiable references in ASL/ASST/AOU/IRCCS, with use cases covering PARM, incident reporting and claims management.
SLAs on uptime (>= 99.5%), support response times and penalties, rather than generic "best effort" commitments.
Help desk, support for the Risk Manager and documentation in Italian, with fast escalation to the product team.
A shared development roadmap and the ability to propose improvements: avoid "black box" suppliers.
Method
The checklist is not a marketing questionnaire; it is a governance tool. These are the four levers that improve the quality of the decision.
Turn each criterion into a binding question in the tender specifications: use the code (e.g. CN-01) as a unique identifier for supplier responses and for comparing vendors.
Ask the supplier to show live how it meets each criterion. Assign a rating by level: compliant / partial / absent / not applicable, with evidence (screenshot, document).
Not all criteria carry the same weight for your organisation. Agree a weighting with the Medical Directorate, Quality Office and IT before making the comparison, to avoid after-the-fact bias.
Report the selection methodology in the annual report and to the Claims Assessment Committee: a traceable selection is an integral part of the clinical risk governance required by the Gelli-Bianco Law.
FAQ
Healthcare Risk Management software supports the clinical risk management functions required by Law 24/2017: it collects and classifies reports of adverse events and near misses, manages the single risk register and the Annual Risk Management Plan (PARM), tracks corrective actions, patient feedback and claims, and produces the annual report for the Directorate.
The main references are Law 24/2017 (Gelli-Bianco), fully in force from 16 March 2026, Legislative Decree 502/1992 and Law 208/2015 on clinical governance, the 19 ministerial recommendations on sentinel events, the GDPR for the processing of health data and, for relevant suppliers, Legislative Decree 138/2024 transposing the NIS2 Directive.
For SSN organisations the decisive criterion is not on-premise versus cloud, but the qualification of the infrastructure. ACN-qualified cloud (formerly AgID) is compatible with health data sovereignty and allows rapid updates, disaster recovery and scalability. On-premise remains a legitimate choice if the organisation has the in-house skills and capacity to guarantee RTO/RPO consistent with the criticality of the data.
The most robust indicators are: the number of active reports per 1,000 inpatient days, the share of reports closed within SLA, the average time to complete a report and the distribution by operational unit. Healthy adoption tends to grow in the first 6-12 months and then stabilise: a decline suggests usability problems or a lack of trust in the feedback received.
Practical discussion · Free · ~45 min
Once you have read the checklist, we can discuss the critical points of your organisation's tender specifications one-to-one. The Easy Health team supports the Risk Manager in assessing suppliers and in drawing up the Annual Risk Management Plan.
We show how EasyRisk meets each criterion in this checklist, point by point. The session is free and takes place remotely in about 45 minutes.
Request a meetingTell us how care is organised in your area: we'll prepare a demo on your own pathways, not on a textbook case.